Open Cell

LoneStar Air Sealers · Open-Cell Spray Foam

Texas heat.
Meet a better
building envelope.

Open-cell spray foam insulation for suitable walls, rooflines and new construction assemblies. Built around your project, from the framing out.

Spray foam insulation installed along a building roofline and framing
COMFORT STARTS WITH THE ENVELOPE.
NEW CONSTRUCTIONREMODELS & ADDITIONSWALLS & ROOFLINES
Spray foam insulation Open-Cell Spray Foam
Insulation that fits the space

Fill the cavities.
Plan for the whole building.

Open-cell spray polyurethane foam is a low-density insulation applied to suitable, accessible surfaces. It expands during installation to fill irregular spaces and insulate the specified area.

At the product’s approved thickness and with continuous installation and properly detailed connections, it can also form part of the building’s air-control layer. That makes coverage, depth and transitions just as important as the material itself.

LoneStar Air Sealers installs spray foam for builders and renovation projects throughout the Brazos Valley and Montgomery County. We help define the application around your building’s assemblies and goals.

More than filling a cavity

Think insulation.
Think air control.

Comfort depends on how heat and air move through the building. Open-cell foam can address insulation and air leakage within suitable assemblies when the installation meets the selected product’s requirements.

01Thermal performance: Specify installed depth around the product’s rated R-value and the project requirements.
02Continuity: Review corners, edges and connections so the insulation and air-control layers work together.
03Whole-building planning: Account for ventilation, indoor humidity and HVAC needs alongside insulation.
Where open-cell may fit

Your project.
The right application.

Open-cell foam belongs in an assembly designed for its properties. We review the framing, available depth, exposure and intended use before defining the scope.

01 / APPLICATION

New construction walls

Insulate accessible wall cavities before finishes go in. Coverage, cavity depth and connections to adjacent assemblies belong in the insulation plan.

02 / APPLICATION

Roofline & attic assemblies

Explore open-cell foam for suitable roofline assemblies. Roof condition, moisture control, ventilation and HVAC requirements need to be considered together.

03 / APPLICATION

Remodels & additions

Take advantage of exposed framing during a renovation. We review the accessible areas and how new insulation connects to the existing building envelope.

04 / APPLICATION

Custom homes

Plan insulation around the home’s layout and assemblies. Send plans so rooflines, wall sections, coverage areas and performance goals can be reviewed.

05 / APPLICATION

Selected commercial spaces

Discuss open-cell foam for suitable commercial wall and roof assemblies. Substrate, occupancy, moisture exposure and protective coverings guide suitability.

06 / APPLICATION

Interior sound-control goals

Open-cell foam may be considered as part of a sound-control assembly. Results depend on the entire wall or floor system; insulation alone does not make a room soundproof.

Choose the material around the assembly

Open-cell or closed-cell?
Start with what you need.

Both are spray polyurethane foam, but they have different properties. The right choice depends on space, moisture conditions and the design of the assembly.

Key differences to discuss for your project
ConsiderationOpen-cell foamClosed-cell foam
MaterialLower-density foam with an open-cell structure.Higher-density foam with a closed-cell structure.
R-value per inchGenerally lower; more depth is needed for the same R-value.Generally higher; useful when available depth is limited.
Vapor controlGenerally more vapor-permeable; assembly-specific vapor control may be needed.Generally less vapor-permeable; vapor-retarder performance depends on the product and thickness.
Air controlCan provide air control at its approved thickness with continuous installation.Can provide air control at its approved thickness with continuous installation.
SelectionConsider available cavity depth, moisture design, coverage and project goals.Consider depth, moisture exposure and any documented assembly requirements.

Specific R-values, air-barrier thicknesses and vapor properties come from the selected product’s documentation. Neither material replaces roof repairs, flashing or a properly designed water-management system.

Considering roofline insulation?

A sealed attic needs
a complete plan.

Moving insulation to the roofline changes the building enclosure. The roof, attic and mechanical systems need to be reviewed together before making that change.

01 / ROOF & MOISTURE

Start with a sound assembly.

Resolve leaks and unsuitable substrate conditions first. Roof materials, climate and indoor humidity affect the moisture-control approach.

02 / ENCLOSURE

Define the boundaries.

Identify where insulation and air control will run, including roof-to-wall connections, gables and openings. Venting details follow the chosen assembly design.

03 / MECHANICAL SYSTEMS

Coordinate the systems.

Review ventilation, humidity control and HVAC requirements. Existing combustion appliances may require additional evaluation when the enclosure changes.

From plans to installation

Get the details right
before the spray starts.

01Review the project: Plans, coverage areas, target performance, framing and access.
02Prepare the site: Suitable substrates, protection of adjacent surfaces and installation coordination.
03Install to the specification: Product requirements guide thickness, application conditions and required protective coverings.
04Plan reoccupancy: Follow the specific product and installer instructions for ventilation and return to the space.
For builders & homeowners

Let’s price the actual project.

Wall sections, roof geometry, installed depth and access all affect the scope. Send plans when available so coverage and details can be reviewed before installation.

Planning a new build? Ask about blower door testing with your new-construction insulation quote. It can help assess the completed enclosure’s airtightness and identify remaining air leakage.
Before we insulate it

Your open-cell questions, answered.

What is open-cell spray foam?

It is a low-density spray polyurethane foam insulation. It expands during application to fill suitable cavities and irregular spaces. Product properties and installed thickness determine its thermal and air-control performance.

How thick does it need to be?

Thickness depends on the selected product’s rated R-value, assembly design and applicable project requirements. Air-barrier performance also has a product-specific minimum thickness. We review those requirements rather than using one thickness for every application.

Is open-cell foam waterproof?

No. It should not be used as a waterproofing layer. Roof leaks, bulk-water entry and moisture conditions need to be addressed through the assembly’s water- and moisture-management design.

Can it be installed at the roofline?

It may be appropriate in a properly designed roof assembly. Roof condition, indoor humidity, vapor control, ventilation and mechanical systems need to be reviewed. A vented attic should not simply be closed off without a coordinated plan.

Will spray foam lower my energy bills?

Improving insulation and reducing air leakage can help reduce heating and cooling demand. Actual results depend on the starting condition of the building, coverage, HVAC performance, weather and how the space is used. A fixed savings percentage is not promised.

Does open-cell foam make a room soundproof?

No. It may be used as part of a sound-control assembly, but sound travels through framing, finishes, openings and other paths. The performance of the complete assembly matters.

Does the foam need to be covered?

Required thermal or ignition protection depends on the product approval, location, intended use and applicable requirements. The project scope should identify the protective coverings or approved assemblies needed for the installation.

Can we stay in the building during installation?

Plan access and occupancy with the installer before work begins. Application ventilation, restricted access and reoccupancy follow the specific product and installation instructions. There is no single return time that should be assumed for every product or site.

What do you need for a quote?

Send your project location, plans or dimensions, photos, framing details and the areas you want insulated. Tell us whether it is new construction, a remodel or an existing building, and include your anticipated schedule.

Let’s build a better envelope

Have plans?
Let’s talk foam.

Tell us what you’re building, improving or opening up. We’ll help define the next step for your insulation project.

Serving Bryan–College Station, the Brazos Valley and Montgomery County, including Montgomery, Conroe and surrounding communities.

Request an open-cell foam quote