LoneStar Air Sealers · Blower Door Testing

How leaky
is your house?

Stop guessing where your comfort is going. Blower door testing measures building-envelope air leakage so you can plan the next step with real information.

Illustration of a blower door fan and pressure gauge installed in a doorwayMEASURE THE AIR LEAKAGE.ILLUSTRATION · EQUIPMENT SETUP VARIES
NEW CONSTRUCTIONEXISTING HOMESAIR-LEAKAGE DIAGNOSTICS
A number you can work with

Find out how much air
is getting through.

A blower door uses a calibrated fan installed in an exterior doorway to create a controlled pressure difference between indoors and outdoors. The equipment measures the airflow needed to maintain that difference.

The result describes the enclosure’s air leakage under test conditions. It provides a useful starting point for new-construction verification, existing-home diagnostics and measuring improvements after air sealing.

LoneStar Air Sealers provides blower door testing in Bryan–College Station, the Brazos Valley and Montgomery County.

Measure first. Investigate next.

The test measures leakage.
Diagnostics help locate it.

A whole-building result shows how much air the enclosure leaks. Locating individual pathways takes additional investigation while the pressure difference makes leakage easier to detect.

01Measure: Establish the building’s air-leakage result under the selected test procedure.
02Investigate: Discuss leak-location diagnostics using visual inspection, a smoke pen or thermal imaging where conditions permit.
03Prioritize: Use the findings to discuss air-sealing opportunities and any additional assessment needed.

Diagnostic methods and leak-location work depend on the booked scope, access and site conditions. Thermal imaging is most useful when there is an adequate temperature difference.

What brings you to the test?

Building new?
Tracking down drafts?

Tell us why you need testing so we can confirm the preparation, procedure and documentation appropriate for your project.

01 / TESTING APPLICATION

New construction

Measure the completed building enclosure’s air leakage against the project’s specified target. Share the permit requirements and required report format before scheduling.

02 / TESTING APPLICATION

Existing-home diagnostics

Investigate drafts and suspected air leakage with a measured baseline. Combine testing with a scoped leak investigation to help prioritize appropriate air-sealing work.

03 / TESTING APPLICATION

Before & after air sealing

Compare results before and after improvement work using consistent test preparation and conditions. Retesting helps assess the change in measured enclosure leakage.

Understand the results

CFM50. ACH50.
What do they mean?

Many enclosure tests report leakage at a pressure difference of 50 pascals. The reporting metric depends on the test requirements and the building information provided.

CFM50

Airflow in cubic feet per minute at a 50-pascal pressure difference. It describes the airflow needed to maintain the test pressure.

ACH50

Air changes per hour at 50 pascals. It relates the measured airflow to the tested enclosure volume: CFM50 × 60 ÷ volume in cubic feet.

ACH50 is a test-condition metric, not the home’s everyday natural ventilation rate. Accurate enclosure dimensions and boundaries matter when calculating and interpreting the result.

Know what to expect

A straightforward test.
A properly prepared building.

01 / CONFIRM

Review the project.

Share the address, floor plan, ceiling heights, test purpose and any required performance target or report form. Confirm the building’s readiness before scheduling.

02 / PREPARE & TEST

Set up the enclosure.

The technician reviews site conditions, prepares openings and equipment according to the test procedure, installs the fan and records the measurements.

03 / REVIEW

Understand the next step.

Review the measured result and agreed documentation. If additional leak investigation, sealing or retesting is needed, discuss that scope separately.

For builders & project teams

Bring the requirements.
We’ll review the test.

For permit or project verification, send the applicable test target, required procedure and reporting form before booking. Acceptance depends on the authority or program reviewing the result.

01Requirements: Provide the project’s specified leakage limit and documentation needs.
02Readiness: Confirm the enclosure and installed systems are ready for the required test stage.
03Scheduling: Allow time for corrective work and retesting if the measured result exceeds the target.
A building works as a system

Better air control.
A plan for fresh air.

Reducing uncontrolled air leakage and providing appropriate ventilation are related parts of a good enclosure plan. A blower door result helps inform the conversation; it does not replace ventilation design or a complete HVAC assessment.

Before your appointment: Let us know about fireplaces, solid-fuel appliances, combustion equipment or unusual site conditions. The technician will confirm preparation and whether conditions are suitable for testing.
Before we bring the fan

Your blower door questions, answered.

What does a blower door test measure?

It measures building-envelope air leakage under a controlled pressure difference. Results can be reported as airflow or normalized metrics such as ACH50, depending on the test purpose and available building information.

Will the test show exactly where every leak is?

The fan measurement gives a whole-building leakage result. Finding individual pathways requires additional diagnostics. Ask about the scope of leak investigation, smoke-pen checks or thermal imaging when scheduling.

What result does my house need to pass?

The target depends on the applicable project, jurisdiction or program requirements. Share the specified limit and reporting form before booking. We do not assume one passing number applies to every building.

Is this the same as duct leakage testing?

No. A blower door measures enclosure leakage. Duct leakage testing evaluates the duct system and uses a different setup. Confirm which test or combination your project requires.

Is blower door testing only for new homes?

No. Existing homes can be tested to establish a leakage baseline, investigate comfort concerns or compare results before and after air-sealing work.

How should I prepare?

Follow the technician’s project-specific instructions. Let us know about operating fireplaces, combustion appliances, ongoing construction and access restrictions. Openings and mechanical systems are configured according to the applicable test procedure.

How long does an appointment take?

Timing depends on building size, setup, readiness, test procedure and whether leak diagnostics are included. Share your project details so we can discuss scheduling and access.

What happens if the result is above the target?

Review the measured result and test setup, then discuss leak investigation and corrective air sealing. A separate retest may be needed after work is completed. Passing is not guaranteed before testing.

Can you test after air-sealing work?

Yes, retesting can help evaluate changes in measured enclosure leakage. Comparable preparation and testing methods are important when reviewing before-and-after results.

Let’s put a number to it

Building new?
Chasing a draft?

Tell us what you need to learn—or what your project needs documented.

Send the address, approximate size, ceiling heights, preferred timing and any test requirements. Serving the Brazos Valley and Montgomery County.

Request blower door testing